1-468 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MP Operator complaint (standalone)
Clearing MP keyboard trouble
(continued)
7
Replace the keyboard cable.
8
Perform the common procedure
Placing MP position from service
(standalone).
9
Test again to see if the keys respond on the keyboard.
10
Perform the common procedure
Removing MP position from service
(standalone).
At the TAMI
11
To access the Diagnostics screen from the TAMI main menu, enter:
>5
and press the Enter key.
TAMI response
12
To run the diagnostic test on the keyboard, enter:
>POSDIAG n MANKEY
and press the Enter key.
where
n
is the position number (0, 1,2, or 3)
Note: The user can only select ManB positions.
13
Press every key on the MP keyboard and check that the keys are highlighted
on the MP display. Follow the prompts to exit the diagnostic.
14
Replace the keyboard. Refer to
Card Replacement Procedures and return to
this point.
If the keys
Do
respond
step 27
do not respond
step 10
If
Do
test passes
step 17
any key fails
step 14
Enter TPC Diagnostics command: