1-98 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing an 8-in. or a 5.25-in. disk drive unit
(continued)
10
From the MAP response in step 9, record the area (floor, row, bay, and shelf)
of the DDU that requires replacement.
11
To manually busy the controller, type
>BSY
and press Enter.
12
To stop the DDU manually, type
>STOP
and press Enter.
Note: Wait until the DDU spins down before you proceed to step 13. The
status code
spun_down
appears under the Drive_State header on the
MAP display.
13
To off-line the disk drive, type
>OFFL
and press Enter.
If the BSY command
Do
passed
step 12
failed
step 67
If the STOP command
Do
passed
step 13
failed
step 68
Process may take up to 3 minutes.
Failed
Drive is disconnected
Site
Flr RPos
Bay–id
Shf Description Slot
EqPec
HOST
01
A00
IOE 00
04
IOC 0 DDU
02
1X62
HOST
01
A00
IOE 00
04
IOC 0 DDU
22
0X67