Trouble locating and clearing procedures (continued) 1-469
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
TOPS MP Operator complaint (standalone)
Clearing MP keyboard trouble
(continued)
At the TAMI
15
To run the MP manual keyboard test, enter:
>POSDIAG n MANKEY
and press the Enter key.
where
n
is the position number (0, 1,2, or 3)
Note: The user can only select ManB positions.
16
Press every key on the MP keyboard and check that the keys are highlighted
on the MP display. Follow the prompts to exit the diagnostic.
17
To run the terminal controller test from the Diagnostics screen of the TAMI,
enter:
>POSDIAG n TCD
and press the Enter key.
where
n
is the position number (0, 1,2, or 3)
18
Replace the MP position base. Refer to
Card Replacement Procedures and
return to this point.
At the TAMI
19
To run the MP manual keyboard test, enter:
>POSDIAG n MANKEY
and press the Enter key.
where
n
is the position number (0, 1,2, or 3)
Note: The user can only select ManB positions.
If
Do
test passes
step 26
any key fails
step 17
If test
Do
passes
step 21
fails
step 18