Brand number
Set the brand number.
The brand number can be changed by pressing the [ACCUM] key
or the [PRESET TARE WEIGHT] key when
is display-
ed.
Setting range: 0 to 7; Unit: 1 D
The default is [0].
FINAL
Sets the measurement target value
Setting range: 000000 to 999999; Unit: 1 D
The default is [000000].
FREEFALL (Over-
shoot)
Sets the overshoot target value
Setting range: –999999 to 999999; Unit: 1 D
The default is [000000].
In simple mode, D. (Fine) FLOW output is ON when the value of
[FINAL (SET1) – F.FALL (Overshoot) (SET2)]is obtained; in sequen-
tial mode the D. (Fine) FLOW is OFF when the value of D. (Fine)
FLOW is reached.
When[FINAL ≤ F.FALL (Overshoot)], SQ.ERR 3 occurs when the
start signal is input.
PRELIMINARY 1
Set the value of PRELIMINARY 1.
Setting range: 000000 to 999999; Unit: 1 D
The default is [000000].
In sequential mode, M. (Middle) FLOW output is ON when the
value of [FINAL (SET1) – PRELIM 1(SET3)]is obtained; in simple
mode the D. (Fine) FLOW is OFF when the value of M. (Middle)
FLOW is reached.
When the start signal is input and [FINAL ≤ F.FALL (Overshoot)],
SQ.ERR 3 occurs. If one before ≥ 1 or the head is measured before
the setting, weighing ixed quantity ≤ PRELIM1.
PRELIMINARY 2
Set the value of PRELIMINARY 2.
Setting range: 000000 to 999999; Unit: 1 D
The default is [000000].
In sequential mode, F. (Coarse) FLOW output is ON when the
value of [FINAL (SET1) – PRELIM 2(SET4)]is obtained; in simple
mode the F. (Coarse) FLOW is OFF when the value of [FINAL(SET1)
– PRELIM 2(SET4)] is reached.
When [FINAL ≥ PRELIM 2], [PRELIM 1 ≥ PRELIM 2] or [F. (Coarse)
FLOW ≤ PRELIM 2], SQ.ERR 3 occurs when start signal is input.
OVER
Set the value of OVER.
Setting range: 00000 to 99999; Unit: 1 D
The default is [00000].
When weighing result [FINAL (SET1) + OVER (SET5)] is exceeded,
over output turns on.
UNDER
Set the value of UNDER.
Setting range: 00000 to 99999; Unit: 1 D
The default is [00000].
When weighing result [FINAL (SET1) – OVER (SET6)] is exceeded,
under output turns on.
Weight indicator CSD-903
11 Weighing mode
EN-92
Minebea Intec
Summary of Contents for CSD-903