background image

WARNING:  Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance 
may result in property damage or personal injury.

CAUTION:  Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.

1.

 Remove the safety screen, glass door and media.

2. 

Disengage the air shutter control rod by wiggling and pushing the rod to the left.

*

3. 

Remove the 10 screws (5 per side) that secure the media tray and burner assembly in place. Lift this assembly up and out of the appliance.

4.

 Using a deep socket wrench, remove the orifi ce from the fi rebox and replace with the orifi ce supplied (#37 for NG, #52 for LP). 

5. 

Remove the two screws from the valve regulator and remove the regulator, replace with the one supplied (refer to Figure 1). 

 

This conversion kit shall be installed by a qualifi ed service agency in accordance with the 
manufacturer’s instructions and all applicable codes and requirements of the authority having 
jurisdiction.  If the information in these instructions is not followed exactly, a fi re, explosion 
or production of carbon monoxide may result causing property damage, personal injury or 
loss of life.  The qualifi ed service agency is responsible for the proper installation of this kit.  
The installation is not proper and complete until the operation of the converted appliance is 
checked as specifi ed in the owner instructions supplied with the kit.

FUEL CONVERSION KITS FOR MODEL

LV38N / LV38N2

These kits are for use at altitudes of 0 to 4500 feet.

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.

CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada        •  (705)721-1212         •  fax (705)722-6031       • www.napoleonfireplaces.com

                                                                                                                                                                                          

Continued on reverse 

 W175-0423, Propane to Natural Gas Includes; 

 

STEP MOTOR / REGULATOR 

1

 

#37 BURNER ORIFICE 

1  

 

CONVERSION DATA LABEL 

1

 

NATURAL GAS PILOT INJECTOR 

1

W415-1581 / B / 03.16.16

6. 

Remove the pilot hood from the pilot assembly by  removing the retaining clip and pulling vertically. Use a 

5

/

32

” 

Allen key to unscrew the injector. Replace the pilot injector with the one supplied. Re-assemble the pilot hood onto      

    the assembly ensuring key position for proper alignment. Reinstall retaining clip.

7.

 The conversion data label must be fi lled out and attached adjacent to the valve.

8.

 Re-install the burner and media tray assembly. Turn on the electrical supply to the appliance. 

9. 

Verify the center of the pilot hood is 1”    1/8” away from the fi rst burner port (refer to Figure 2).

10. 

Engage the air shutter control rod by locating the stud on the shutter with the grommet on the    

       

control rod. Wiggle and push the knob to the right until the stud is totally inserted in the grommet.

PILOT

HOOD

PILOT

INJECTOR

Figure 1

Figure 2

 W175-0424, Natural Gas to Propane Includes; 

 

STEP MOTOR / REGULATOR 

1

 

#52 BURNER ORIFICE 

1  

 

CONVERSION DATA LABEL 

1

 

PROPANE GAS PILOT INJECTOR 

1

+

-

A rubber grommet inserted into the control rod provides a snug fi t. 

Reviews: