Item
Function No.
Number Return command set value
4-step check S0 operation con-
dition
70
23
0: Always OFF
1: On when both S1 and S2 outputs are OFF
2: On when both S1 and S3 outputs are OFF
3: On when both S1 and S4 outputs are OFF
4: On when both S2 and S3 outputs are OFF
5: On when both S2 and S4 outputs are OFF
6: On when both S3 and S4 outputs are OFF
7: On when Gross weight ≥ Maximum load
Comparator hysteresis operati-
on condition
70
24
0: On delay; 1: Of delay
Comparator hysteresis data
width
70
25
00 to 99; Unit: 1 D)
Comparator hysteresis time
width
70
26
00 to 99; Unit: 0.1 s)
BCD output operation mode
70
30
0: Stream
1: SYNC. WITH PRINT
2: SYNC. WITH ACCUM
3: SYNC. WITH FINISH
BCD output target
70
31
0: Display interlock; 1: Gross value; 2: Net weight;
3: Tare weight; 4: Accumulation total
5: Accumulation frequency
BCD output logic
70
32
0000 to 1111 (0: Negative logic; 1: Positive logic)
10
0
: Data output logic (Weighing operation and
Decimal point)
10
1
: Polarity logic
10
2
: Flag logic (ERROR, OVER, STABLE,
GROSS WEIGHT)
10
3
: P.C. logic
BCD P.C. (Print command)
70
33
0: 125 ms; 1: 25 ms; 2: 5 ms
BCD output time
70
34
0: 4 times/s; 1: 20 times/s; 0: 4 times/s;
1: 20 times/s
S-I/F automatic print operation 70
37
0: OFF; 1: SYNC. WITH PRINT;
2: SYNC. WITH ACCUM; 3: SYNC. WITH FINISH
RS-232C operating mode
70
40
0: Command mode; 1: Stream
2: SYNC. WITH PRINT; 3: SYNC. WITH ACCUM
4: SYNC. WITH FINISH
RS-232C output target
70
41
0: Display interlock; 1: Gross value; 2: Net weight
3: Load display data with condition
18 Options
Weight indicator CSD-903
Minebea Intec
EN-195
Summary of Contents for CSD-903
Page 243: ......