Weighing
Enforce within the [MAXTIME
OF COMPENSATION]
Time
Net
Calming time (waiting time)
Post-batching time
Waiting time after
post-batching
Stable
Finish
+tolerance (over setpoint)
OK
-tolerance (under setpoint)
Batch start
Setpoint – Preset 2
Setpoint – Preset 1
Setpoint – Overshoot
Setpoint
0
Batch start delay timer
Batch monitoring timer
Setpoint – Under setpoint
Condition
Coarse flow
Middle flow
Fine flow
11.4.4
Automatic overshoot compensation
This function sets the overshoot value automatically by anticipating the next overshoot
value from the actual overshoot value in continuous weighing operation.
The next overshoot set data uses the moving average value for data from 4 previous
overshoots.
When using this function, set automatic overshoot compensation to [VALID] and set the
value of [Automatic Free Fall efective width].
Refer to Chapter
.
When batch error (= |weighed value - FINAL value|) exceeds the automatic overshoot
efective width set value, it is treated as invalid data and automatic overshoot calculation
is not performed.
Automatic overshoot is not calculated if the value of automatic overshoot efective width
is 0.
Automatic overshoot compensation is cleared by changing the set value or when the
power supply is turned OFF.
Weight indicator CSD-903
11 Weighing mode
EN-104