18.3.13.1 When the setting of function F-41 (RS-232C/422/485) or function F-48 (standard RS-485) is set
to (LOAD DISPLAY), (GROSS), or (NET)
Return (device → Host)
10
8
6
4
2
12
14
@
9
9
0
0
Terminator
Command No.
Load data
Load data sign
10
8
6
4
2
12
14
@
9
9
0
0
–
2
3
1
Terminator
10
8
6
4
2
12
14
@
9
9
0
0
+
2
3
1
.
0
Terminator
10
8
6
4
2
12
14
@
9
9
0
0
+
L
O
Terminator
10
8
6
4
2
12
14
@
9
9
0
0
–
L
O
Terminator
18.3.13.2 When the setting by function F-41 (RS-232C/422/485) or function F-48 (standard RS-485) is set
to (Conditional weight display data)
2
4
6
8
10
12
14
16
C1
C2
C3
C4
,
,
C5
C6
C7
C8
C9 C10 C11 C12 C13 C14 C15
Sign
Unit
Weight data (8 digits)
Header 2
Header 1
Terminator
Header 1
Header 2
Sign
Load data (8 digits)
Unit
C1 C2 Description C3 C4 Description C5 Description C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 Description
O L Overload
N T Net Plus
1
2 3
g Gram
S T Stable
G S Gross
weight
- Minus
0 .
1
2 3 k g Kilogram
U S Unstable
O L
t
Ton
l
b Pound
N Newton
k N Kilonewton
Weight indicator CSD-903
18 Options
EN-204
Minebea Intec
Summary of Contents for CSD-903