Operates at the input of start signal
Condition
Time
Coarse flow weighing
delay timer
Middle flow weighing
delay timer
Calming time (waiting time)
Stable
Finish
+tolerance (over setpoint)
OK
-tolerance (under setpoint)
Start
Coarse flow
Middle flow
Fine flow
Tare
Setpoint - Preset 2
Setpoint - Preset 1
Setpoint - Overshoot
Setpoint
0
Fine flow weighing
delay timer
Weighing
Can be changed to
simple comparison
11.4 Sequential mode
Sequential mode includes sequential batch mode and sequential discharge mode.
Supplementary inlow, initial batching, nozzle batching and automatic overshoot
compensation can be set if necessary.
11.4.1
Sequential batch mode (batch in)
Sequential batch mode controls the weighing sequence depending on the increase in
weighing value during raw material inlow.
Judgment condition
Status display
Judgment condition
Z-BAND
|Gross weight or (Net weight)| ≤ ZERO BAND (SET7).
F. (Coarse) FLOW
Net weight ≥ [Final (SET1) – Prelim 2 (SET4)]
M. (Middle) FLOW
Net weight ≥ [Final (SET1) – Prelim 1 (SET3)]
D. (Fine) FLOW
Net weight ≥ [Final (SET1) – Overshoot (SET2)]
UNDER
Net weight < [Final (SET1) – Under (SET6)]
Weight indicator CSD-903
11 Weighing mode
EN-98