Net weight
(larger)
Net weight
(smaller)
S1 Output ON
S1 Output OFF
S1 setting value
11.5.3
Operation of S0 in control mode
S0 can perform eight operations in this check mode.
Select in function mode (F-23).
The default is [Always of].
Note:
The ON/OFF status for each output may difer depending on selection. If an
inappropriate mode is selected, the ON/OFF status may be incorrect, leading to
malfunction of peripheral instruments.
S0 output operation is shown at the time F-23 setting.
Setting by F-23
Operation
0
Always OFF
1
Turns ON when S1 and S2 outputs are OFF
2
Turns ON when S1 and S3 outputs are OFF
3
Turns ON when S1 and S4 outputs are OFF
4
Turns ON when S2 and S3 outputs are OFF
5
Turns ON when S2 and S4 outputs are OFF
6
Turns ON when S3 and S4 outputs are OFF
7
Turns on when Gross weight ≥ Maximum load
Next, operation with S0 output set to [1] and F-23 from [1] to [6] is shown.
The same applies for [2] to [6] with F-23.
-
When S1 and S2 are set to[Set value or more] with F-22
S1 output turns ON when S1 set value ≤ comparison value.
S2 output turns ON when S2 set value ≤ comparison value.
S0 output turns ON when S1 set value > comparison value and S2 set value >
comparison value.