Near zero (ZERO BAND) Sets the value to output the near zero signal.
Setting range: 000000 to 999999; Unit: 1 D
The default is [000000].
When the weighing result is less than (ixed value – over), un-
der output turns on.
FULL
Set the value of FULL.
Setting range: 000000 to 999999; Unit: 1 D
The default is [000000].
When the Gross weight or the Net weight exceeds the Full
value, FULL output turns ON.
Note:
Set the storage destination to Internal RAM when the set value is continuously changed
and the number of EEPROM rewrites might exceed 1 000 000.
11.3 Simple mode
The sub-modes for simple mode are simple batching mode and simple discharge mode.
To set simple mode, refer to Chapter
.
To set batching mode and discharge mode, refer to Chapter
.
11.3.1
Simple batch mode
Simple batch mode is an output mode. The results of comparing the weighing value
increase for batching mode is compared to a set value to meet a judgment condition.
Judgment condition
Status display
Judgment condition
Z-BAND
?Gross weight or Net weight)? ≤ ZERO BAND (SET7)
F. (Coarse) FLOW
Net weight ≥ [Final (SET1) – Prelim 2 (SET4)]
M. (Middle) FLOW
Net weight ≥ [Final (SET1) – Prelim 1 (SET3)]
D. (Fine) FLOW
Net weight ≥ [Final (SET1) – Prelim 1 (SET3)]
UNDER
Net weight < [Final (SET1) – Under (SET6)]
OVER
Net weight > [Final (SET1) + Over (SET5)]
OK
[Final (SET1) – Under (SET6) ≤ Net weight ≤ Final (SET1) + Over
(SET5)]
Operating explanations
-
When –net weight reaches [Final value – Prelim 2] Coarse low turns ON. When the
start signal is input, the comparison from Coarse inlow, Middle inlow and Fine
inlow is prohibited during the Middle low comparison.
-
When the –net weight reaches[Final value – Prelim 1] Middle low turns ON. When the
start signal is input, the comparison from Coarse inlow, Middle inlow and Fine
inlow is prohibited during the Fine low comparison.
-
When the net weight reaches [Final – Overshoot], Fine low turns ON.