Item
Function No.
Setting
Contents
0*
Command mode
RS-422/485 operation
mode
F-49
1
Stream mode
Accumulation function
operating condition
F-50
000 to 121
000*
Accumulation command operation
10
0
digit: 0 = only when stable; 1 = Always
Automatic accumulation operation
10
1
digit: 0 = OFF
1 = Synchronizing with inish
2 = Automatic accumulation
when stable
Automatic accumulation condition
10
3
digit: 0 = In OK mode only
1 = Unconditional
0*
Changeover by function
1
Changeover by external control input
Brand changeover
F-51
2
Changeover by communication
0*
Brand 0
1
Brand 1
2
Brand 2
3
Brand 3
4
Brand 4
5
Brand 5
6
Brand 6
Brand number
F-52
7
Brand 7
0*
OFF
1
Print Input
2
Hold Input
3
Inlow start
4
Emergency stop
5
Zero clear
6
Tare weight clear
7
Accumulation clear
8
Weighing comparison
Setting F key operation
F-55
9
Forced inlow inish
0*
OFF
1
[ON-OF] key operation
2
[SET] key operation
External control INPUT1
operation setting (Settings
1 to 8 operate all the time;
settings 9 to 27 operate
only in weighing mode.)
F-60
3
[ACCUM] key operation
Weight indicator CSD-903
9 Function mode
EN-72