Status display
Judgment condition
OK
[Final (SET1) – Under (SET6) ≤ Net weight ≤ Final (SET1) + Over
(SET5)]
Operating explanations
-
Coarse low, Middle low and Fine low turn on when the start signal is input.
Tare weight cancellation can be set to start at the same time as the start signal.
-
When the net weight reaches [Final value – Prelim 2], Coarse low turns OFF.
-
When net weight reaches [Final value – Prelim 1], Middle low turns OFF.
-
When the net weight reaches [Final value – Overshoot], Fine low turns OFF.
-
The comparison target of near zero can be selected from Gross weight and Net
weight.
-
Near Zero is a simple operation.
-
After turning of, Coarse low, Middle low and Fine low never turn on before the
next start signal input.
-
Under, Over and OK operate with net weight.
Comparison operation can be changed to simple operation.
-
When [Prelim 2 = 0]is set, Coarse low turns OFF; when [Prelim 1 = 0], Middle low
turns OFF.
-
When automatic tare weight cancellation is operated at the time of low start, set
to [Efective] for [Automatic tare weight cancellation at time of low start].
Refer to Chapter
.
Note:
Output for each comparison is synchronized with A/D sampling.
11 Weighing mode
Weight indicator CSD-903
Minebea Intec
EN-101
Summary of Contents for CSD-903