Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
Sending Event Log Messages as Traps
Use the following options to send Event Log messages as traps.
Table 13-2. Options for Sending Event Log Messages as Traps
Event Level
Description
None (default)
Send no log messages.
All
Send all log messages.
Not INFO
Send the log messages that are not information-only.
Critical
Send critical-level log messages.
Debug
Reserved for ProCurve-internal use.
For example, to configure a trap receiver in a community named "red-team"
with an IP address of 10.28.227.130 to receive only "critical" log messages:
ProCurve(config)# snmp-server trap-receiver
red-team 10.28.227.130 critical
N o t e s
To replace one community name with another for the same IP address, you
must use
no snmp-server host < community-name> < ip-address >
to delete the
unwanted community name. Otherwise, adding a new community name with
an IP address already in use with another community name simply creates
two allowable community name entries for the same management station.
If you do not specify the event level (
[<none | all | non-info | critical | debug>]
)
then the switch does not send event log messages as traps. "Well-Known" traps
and threshold traps (if configured) will still be sent.
Using the CLI To Enable Authentication Traps
N o t e
For this feature to operate, one or more trap receivers must be configured on
the switch. See “Configuring Trap Receivers” on page 13-21.
13-24
Summary of Contents for ProCurve 2610-24
Page 1: ...Management and Configuration Guide 2610 2610 PWR ProCurve Switches R 11 XX www procurve com ...
Page 2: ......
Page 18: ...xvi ...
Page 24: ...Product Documentation xxii ...
Page 54: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 94: ...Using the Web Browser Interface Status Reporting Features 5 24 ...
Page 132: ...Switch Memory and Configuration Multiple Configuration Files 6 38 ...
Page 148: ...Interface Access and System Information System Information 7 16 ...
Page 192: ...Time Protocols SNTP Messages in the Event Log 9 24 ...
Page 256: ...Power Over Ethernet PoE Operation PoE Event Log Messages 11 18 ...
Page 280: ...Port Trunking Port Status and Configuration 12 24 ...
Page 362: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation A 24 ...
Page 438: ...Troubleshooting Restoring a Flash Image C 48 ...
Page 446: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 450: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time E 4 ...
Page 462: ...12 Index ...