Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
SNMP Notification and Traps
The switches covered in this guide support the SNMPv3 notification process.
They also support version 1or version 2c traps. For more information on
version 1 or version 2c traps, see “Trap Features” on page 13-20. The SNMPv3
notification process allows for the messages passed to be authenticated and
encrypted if you choose. To set up a SNMPv3 notification there are three steps:
1. Establish a Notification with the
snmpv3 notify
command.
2. Point the notification to a Address with the
snmpv3 targetaddress
com
mand.
3. Establish a parameter record for the target address with the
snmpv3
params
command.
Syntax
:
[no] snmpv3 notify < notify-name > [ tagvalue < tag-name > ]
This adds or deletes a notification request. To remove
a mapping you only need the
notify-name.
[no] snmpv3 targetaddress < addr-name > params < parms-name>
< IP-Addr >
Add or delete an address where notification messages
are sent.
filter < none | debug | all | not-info | critical >
This filter messages to restrict type of messages
transmitted to address. (Default: none)
udp-port < port >
This specifies the UDP port to use. (Default: 162)
port-mask < mask >
Used to specific a range of UDP ports. ( Default: 0)
addr-mask < mask >
Used to specify a range of address to transit notify
messages. ( Default: 0)
retries < value >
Number times to retransmit a message when no
response is reviewed. (Default: 3)
timeout < value >
How long to wait for a response for the target. ( Default:
1500)
13-18
Summary of Contents for ProCurve 2610-24
Page 1: ...Management and Configuration Guide 2610 2610 PWR ProCurve Switches R 11 XX www procurve com ...
Page 2: ......
Page 18: ...xvi ...
Page 24: ...Product Documentation xxii ...
Page 54: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 94: ...Using the Web Browser Interface Status Reporting Features 5 24 ...
Page 132: ...Switch Memory and Configuration Multiple Configuration Files 6 38 ...
Page 148: ...Interface Access and System Information System Information 7 16 ...
Page 192: ...Time Protocols SNTP Messages in the Event Log 9 24 ...
Page 256: ...Power Over Ethernet PoE Operation PoE Event Log Messages 11 18 ...
Page 280: ...Port Trunking Port Status and Configuration 12 24 ...
Page 362: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation A 24 ...
Page 438: ...Troubleshooting Restoring a Flash Image C 48 ...
Page 446: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 450: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time E 4 ...
Page 462: ...12 Index ...
Page 463: ......