File Transfers
Downloading Switch Software
Note that if you do not specify the flash destination, the Xmodem download
defaults to primary flash.
For example, to download a switch software file named G0103.swi from a PC
(running a terminal emulator program such as HyperTerminal) to primary
flash:
1. Execute the following command in the CLI:
Figure A-4. Example of the Command to Download Switch Software Using
Xmodem
2. Execute the terminal emulator commands to begin the Xmodem transfer.
For example, using HyperTerminal:
a. Click on
Transfer
, then
Send File
.
b. Type the file path and name in the Filename field.
c. In the Protocol field, select
Xmodem
.
d. Click on the
Send
button.
The download can take several minutes, depending on the baud rate used
in the transfer.
3. When the download finishes, you must reboot the switch to implement
the newly downloaded switch software. To do so, use one of the following
commands:
boot system flash <primary | secondary>
Reboots the switch from the selected flash memory.
-or
reload
Reboots the switch from the flash image currently in use.
(For more on these commands, refer to “Rebooting the Switch” on page
6-18.)
4. To confirm that the operating system downloaded correctly, use the
show
system
,
show version
, or
show flash
CLI commands.
Check the
Firmware revision
line. It should show the switch software
version that you downloaded in the preceding steps.
If you need information on primary/secondary flash memory and the boot
commands, refer to “Using Primary and Secondary Flash Image Options” on
page 6-13.
A-13
Summary of Contents for ProCurve 2610-24
Page 1: ...Management and Configuration Guide 2610 2610 PWR ProCurve Switches R 11 XX www procurve com ...
Page 2: ......
Page 18: ...xvi ...
Page 24: ...Product Documentation xxii ...
Page 54: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 94: ...Using the Web Browser Interface Status Reporting Features 5 24 ...
Page 132: ...Switch Memory and Configuration Multiple Configuration Files 6 38 ...
Page 148: ...Interface Access and System Information System Information 7 16 ...
Page 192: ...Time Protocols SNTP Messages in the Event Log 9 24 ...
Page 256: ...Power Over Ethernet PoE Operation PoE Event Log Messages 11 18 ...
Page 280: ...Port Trunking Port Status and Configuration 12 24 ...
Page 362: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation A 24 ...
Page 438: ...Troubleshooting Restoring a Flash Image C 48 ...
Page 446: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 450: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time E 4 ...
Page 462: ...12 Index ...
Page 463: ......