Port Status and Basic Configuration
QoS Passthrough Mode
Note
As stated earlier, use of this QoS-Passthrough-Mode feature generally assumes
that QoS tagged frames are not being sent through the switch. The receipt of
priority 6 or 7 packets may in fact suffer packet drops depending on the traffic
load of non-priority 6 or 7 packets.
Priority Mapping With and Without QoS Passthrough Mode
The switch supports 802.1p VLAN tagging, which is used in conjunction with
the outbound port priority queues to prioritize outbound traffic.
An 802.1Q VLAN tagged packet carries an 802.1p priority setting (0-7). If the
switch receives a tagged packet, it is placed into the appropriate queue based
on the frame's 802.1p priority setting. The mapping with/without QoS
Passthrough Mode is as follows:
802.1p Priority
Setting
Prioritization Queue Placement
Default QoS
Setting
QoS Passthrough
Mode
1
1 (low)
2 (normal)
2
1 (low)
2 (normal)
0 or
Unspecified
2 (normal)
2 (normal)
3
2 (normal)
2 (normal)
4
3 (medium)
2 (normal)
5
3 (medium)
2 (normal)
6
4 (high)
4 (high)
7
4 (high)
4 (high)
How to Enable or Disable QoS Passthrough Mode
QoS Passthrough Mode is disabled by default.
Syntax:
[no] qos-passthrough-mode [optimized | typical]
write memory
reload
The above command sequence enables QoS pass-through
mode. The
no
form of the command sequence disables QoS
pass-through mode. (Default: Disabled)
10-26
Summary of Contents for ProCurve 2610-24
Page 1: ...Management and Configuration Guide 2610 2610 PWR ProCurve Switches R 11 XX www procurve com ...
Page 2: ......
Page 18: ...xvi ...
Page 24: ...Product Documentation xxii ...
Page 54: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 94: ...Using the Web Browser Interface Status Reporting Features 5 24 ...
Page 132: ...Switch Memory and Configuration Multiple Configuration Files 6 38 ...
Page 148: ...Interface Access and System Information System Information 7 16 ...
Page 192: ...Time Protocols SNTP Messages in the Event Log 9 24 ...
Page 256: ...Power Over Ethernet PoE Operation PoE Event Log Messages 11 18 ...
Page 280: ...Port Trunking Port Status and Configuration 12 24 ...
Page 362: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation A 24 ...
Page 438: ...Troubleshooting Restoring a Flash Image C 48 ...
Page 446: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 450: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time E 4 ...
Page 462: ...12 Index ...
Page 463: ......