Port Status and Basic Configuration
Uni-Directional Link Detection (UDLD)
The following commands allow you to configure UDLD via the CLI.
Syntax:
[no] interface <
port-list
> link-keepalive
Enables UDLD on a port or range of ports.
To disable the feature, enter the
no
form of the command.
Default: UDLD disabled
Syntax:
link-keepalive interval <
interval
>
Determines the time interval to send UDLD control packets. The
<interval> parameter specifies how often the ports send a UDLD
packet. You can specify from 10 – 100, in 100 ms increments,
where 10 is 1 second, 11 is 1.1 seconds, and so on.
Default: 50 (5 seconds)
Syntax:
link-keepalive retries <
num
>
Determines the maximum number of retries to send UDLD
control packets. The <num> parameter specifies the maximum
number of times the port will try the health check. You can specify
a value from 3 – 10.
Default: 5
Syntax:
[no] interface <
port-list
> link-keepalive vlan <
vid
>
Assigns a VLAN ID to a UDLD-enabled port for sending of tagged
UDLD control packets.Under default settings, untagged UDLD
packets can still be transmitted and received on tagged only
ports—however, a warning message will be logged.
The
no
form of the command disables UDLD on the specified
port(s).
Default: UDLD packets are untagged; tagged only ports will
transmit and receive untagged UDLD control packets
Enabling UDLD
UDLD is enabled on a per port basis. For example, to enable UDLD on port
a1, enter:
ProCurve(config)#interface al link-keepalive
To enable the feature on a trunk group, enter the appropriate port range. For
example:
ProCurve(config)#interface al-a4 link-keepalive
10-41
Summary of Contents for ProCurve 2610-24
Page 1: ...Management and Configuration Guide 2610 2610 PWR ProCurve Switches R 11 XX www procurve com ...
Page 2: ......
Page 18: ...xvi ...
Page 24: ...Product Documentation xxii ...
Page 54: ...Using the Menu Interface Where To Go From Here 3 16 ...
Page 94: ...Using the Web Browser Interface Status Reporting Features 5 24 ...
Page 132: ...Switch Memory and Configuration Multiple Configuration Files 6 38 ...
Page 148: ...Interface Access and System Information System Information 7 16 ...
Page 192: ...Time Protocols SNTP Messages in the Event Log 9 24 ...
Page 256: ...Power Over Ethernet PoE Operation PoE Event Log Messages 11 18 ...
Page 280: ...Port Trunking Port Status and Configuration 12 24 ...
Page 362: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation A 24 ...
Page 438: ...Troubleshooting Restoring a Flash Image C 48 ...
Page 446: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Page 450: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time E 4 ...
Page 462: ...12 Index ...
Page 463: ......