![horiba Fluorolog-3 Operation Manual Download Page 111](http://html1.mh-extra.com/html/horiba/fluorolog-3/fluorolog-3_operation-manual_2162215111.webp)
Fluorolog-3 v. 2.2 (10 Sep 2002)
Components & Accessories
6-23
Note:
When the sample is
perpendicular the light is
collected at an angle of
22.5°. This orientation
minimizes stray and re-
flected light off the sur-
face of the sample.
Model 1933 Solid Sample Holder
The Model 1933 Solid Sample Holder is designed for samples such as thin films, pow-
ders, pellets, microscope slides, and fibers. The holder consists of a base with graduated
dial, upon which a bracket, a spring clip, and a sample block rest.
Model 1933 Solid Sample Holder with sample block removed.
Installation
1
Remove the present holder.
2
Position the base on the posts.
3
Tighten the two thumbscrews.
For pellets, crystals, creams, gels, powders, and
similar materials:
1
Fill the well of the block.
2
Place a quartz coverslip or Teflon
®
film over the
well.
This holds the sample in place when
vertically positioned.
3
Carefully insert the
block between the
bracket and spring
clip, so that the
sample is perpendicular to the excitation light.