224
FISCHERSCOPE
®
X-RAY
WinFTM PDM: Expanded Product Data Administration and Result Documentation
3.1
Comparative Overview with/without WinFTM PDM
WinFTM PDM (Product Data Management) as a supplemental software is suitable for both WinFTM
BASIC and for WinFTM LIGHT. In both cases, the functional scope of WinFTM PDM is identical.
The following table presents an overview of the available functions with and without PDM.
Function
without PDM
with PDM
Assignment Measurement applica-
tion : Product
1 : 1
Each measurement
application is assigned to
only one product.
1 : n
A measurement applica-
tion can be assigned to
several products
simultaneously.
Product management
Measurement application
related
Product-related
When copying a product the meas-
urement application is …
… duplicated only as a lo-
cal measurement
application
1
1. Local measurement application: The measurement application is assigned to one product
only. After copying, the copied measurement application has no relation or link to its or-
igin. Thus, edits have only a local effect on the assigned product.
… is retained.
Setting up folders or directories for
product management
No
Yes
Normalization and calibration
affects all products linked to the
measurement application
No
Yes
Setting up and storing product-
related print forms
Block print form
Yes
Yes
Final print form
No
Yes
Free block selection (with search
function) with versatile filter
No
Yes
Evaluations using simple print forms:
readings of all blocks are being
evaluated, no block selection, no
customer-specific print form tem-
plates
Yes
Yes
Overview image (on models with
motor-driven XY-stage)
No
Yes
XY-Scan mode (on models with mo-
tor-driven XY-stage)
No
Yes
Summary of Contents for FISCHERSCOPE X-RAY XDLM 231
Page 8: ...6 FISCHERSCOPE X RAY Table of Contents...
Page 14: ...12 FISCHERSCOPE X RAY Safety Information...
Page 30: ...28 FISCHERSCOPE X RAY Set up...
Page 36: ...34 FISCHERSCOPE X RAY WinFTM File Structure...
Page 52: ...50 FISCHERSCOPE X RAY User Interface of the WinFTM Software...
Page 134: ...132 FISCHERSCOPE X RAY Def MA...
Page 146: ...144 FISCHERSCOPE X RAY Programming Coordinates for Automatic Measurements XDLM 237...
Page 186: ...184 FISCHERSCOPE X RAY Pattern Recognition XDLM 237...
Page 192: ...190 FISCHERSCOPE X RAY Cleaning and Maintenance...
Page 202: ...200 FISCHERSCOPE X RAY Addendum...
Page 228: ...226 FISCHERSCOPE X RAY WinFTM SUPER For the Experienced X RAY User...
Page 229: ...FISCHERSCOPE X RAY 227...
Page 232: ......