Getting Started
1/1553-FGC 101 1790 Uen Y
3-39
The tables to be included have to be set up on the Triveni Digital GuideBuilder
equipment. For the configuration of the Triveni Digital GuideBuilder refer to its user
manual.
Note:
In general, all tables generated by Triveni Digital GuideBuilder will be
included in the output.
Operation
External PSIP data insertion requires a valid AVP/SWO/PSIP license be present on
the unit.
Note:
If external table generation is enabled, the unit does not produce tables
internally.
To set up PSIP data insertion, follow the steps below:
1. On the
Service Configuration
page, create the Transport Stream you want to
add the external PSIP information to.
2. Add the required services and components, and adjust the Transport Stream
and component settings.
3. In the
Outputs
widget, select the Transport Stream you want to add the PSIP
data to. In the
Properties
widget, set
Syntax
to
ATSC
and the
External
Generation
to
On - Triveni
. The PSIP accordion panel is now displayed.
4. In the
PSIP
accordion panel, set the
TCP Port
to the port through which your
unit will communicate with the Triveni Digital GuideBuilder equipment. The
default port used by Triveni Digital GuideBuilder is 1250.
5. Set the Maximum PSIP bit rate as required. The more tables that are generated
by the Triveni Digital GuideBuilder, the higher the data rate.
Note:
Once the Triveni Digital GuideBuilder has been set up and a communication
link between the Triveni and your unit is established, the actual bit rate will
be updated in the
Real PSIP bit rate
field.
6. If you want to generate STT, then set the
STT Table Insertion
option to
On
.
Note:
The STT table itself is generated by the Triveni Digital GuideBuilder, and the
generated table is updated with the UTC time on the AVP 4000 unit. UTC
time can be configured by drilling down to
Encoder > Base Unit
in the
Advanced Video Processor Settings
widget on the
Advanced
tab of the
Device Configuration
page, and setting the correct UTC time and date in
the
UTC Time
and
UTC Date
fields in the
Properties
widget. A time server
can be set up in the
SNTP Server
field.
7. In the
Minimum PID
and
Maximum PID
fields, set the PID range for the
generated PSIP tables.
8. Configure the Triveni Digital GuideBuilder equipment as described in its user
manual. Make sure you apply the same Transport Stream and communication
Summary of Contents for AVP 4000
Page 1: ...AVP Family AVP 4000 Software Version 9 31 x REFERENCE GUIDE 1 1553 FGC 101 1790 Uen Y ...
Page 10: ...Preliminary Pages x 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 26: ...Introduction 1 16 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 42: ...Getting Started 3 6 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 140: ...Getting Started 3 104 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 184: ...Front Panel Control 4 44 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 278: ...Advanced Video Processing and Networking 6 4 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 304: ...Advanced Video Processing and Networking 6 30 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 324: ...Preventive Maintenance and Fault finding 8 4 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 346: ...Preventive Maintenance and Fault finding 8 26 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 386: ...Technical Specification B 20 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 388: ...Dolby E PCM Bypass and Switchout C 2 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 390: ...Dolby E PCM Bypass and Switchout C 4 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 392: ...Alarm Lists D 2 1 1553 FGC 101 1790 Uen X BLANK ...
Page 416: ...Logo Creator E 2 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 422: ...Logo Creator E 8 1 1553 FGC 101 1790 Uen Y BLANK ...