Alarm Lists
D-8
1/1553-FGC 101 1790 Uen X
Alarm
Description
Port Number
Alarm ID
Source
Severity
POIS URL not configured
An Acquisition Point Identity is
already configured, but the POIS url
is empty. Signal Processing Events
can't be sent to POIS. Add a valid
POIS URL in the AVP 4000 UI.
0
0000045D
Base Unit
minor
Invalid POIS URL configured
The configured POIS url is not a
valid http url . Signal Processing
Events can't be sent to POIS.Correct
the POIS URL in the AVP 4000 UI.
0
0000045E
Base Unit
minor
POIS connection failure
The unit could not contact the POIS
Server. Check the POIS URL using
a tool like cURL.
0
0000045F
Base Unit
major
Invalid response from POIS
The POIS response xml does not
contain any valid response signal.
Analyse the POIS response XML.
0
00000460
Base Unit
major
PCR Exchange message
timeout
PCR exchange message has not
arrived.
0
00000690
Reflex
controller
warning
Status message timeout
Status message has not arrived.
0
00000691
Reflex
controller
warning
Reflex StatMux algorithm failed
Reflex statistical multiplexing
algorithm returned with an error.
0
00000692
Reflex
controller
warning
MGP Failure
Failed to go online, previous online
device preventing transmission
0
00000491
Base Unit
major
MGP Collision
Potential duplicate transmission
detected
0
00000492
Base Unit
major
MGP Spurious
Spurious MSM packet detected
0
00000493
Base Unit
minor
CSM Contact lost
No CSMs received from Control
System
0
00000680
Base Unit
minor
Datagram loss is greater than 0
The datagram loss rate for the
Transport Stream is greater than 0.
1
000006B0 to
0000073F
Base Unit
major
Sequence number errors in
Transport Stream
There are sequence number errors
in the Transport Stream.
1
000007B0 to
0000083F
Base Unit
major
No data available for Input
Transport Stream
Both Primary and Backup Input
Transport Streams have failed.
1
00000500 to
0000057F
Base Unit
critical
Input Transport Stream running
on Backup
Primary Input Transport Stream has
failed.
1
00000580 to
000005FF
Base Unit
warning
Input Transport Stream missing
Input Transport Stream has failed.
1
00000600 to
0000067F
Base Unit
major
Excessive CC errors on PID
The PID monitor has detected
continuity count errors, which
exceed the windowed threshold.
0
0000BB0 to
0000C2F
Base unit
major
PID on data input network is
missing
The PID monitor has detected a PID
missing for at least the period set by
the user.
0
0000B30 to
0000BAF
Base unit
major
Summary of Contents for AVP 4000
Page 1: ...AVP Family AVP 4000 Software Version 9 31 x REFERENCE GUIDE 1 1553 FGC 101 1790 Uen Y ...
Page 10: ...Preliminary Pages x 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 26: ...Introduction 1 16 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 42: ...Getting Started 3 6 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 140: ...Getting Started 3 104 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 184: ...Front Panel Control 4 44 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 278: ...Advanced Video Processing and Networking 6 4 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 304: ...Advanced Video Processing and Networking 6 30 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 324: ...Preventive Maintenance and Fault finding 8 4 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 346: ...Preventive Maintenance and Fault finding 8 26 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 386: ...Technical Specification B 20 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 388: ...Dolby E PCM Bypass and Switchout C 2 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 390: ...Dolby E PCM Bypass and Switchout C 4 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 392: ...Alarm Lists D 2 1 1553 FGC 101 1790 Uen X BLANK ...
Page 416: ...Logo Creator E 2 1 1553 FGC 101 1790 Uen Y BLANK ...
Page 422: ...Logo Creator E 8 1 1553 FGC 101 1790 Uen Y BLANK ...