logging events display-location
To enable the alarm source location display field for bistate alarms in the output of the
show logging
and
show logging events buffer
command, use the
logging events display-location
command in global
configuration mode.
logging events display-location
no logging events display-location
Syntax Description
This command has no keywords or arguments.
Command Default
The alarm source location display field in
show logging
output is not enabled.
Command Modes
Global configuration
Command History
Modification
Release
This command was introduced.
Release 3.8.0
Usage Guidelines
The output of the
show logging
command for bistate alarms has been enhanced. Previously, the alarm source
field in the output displayed the location of the process that logged the alarm. Use the
logging events
display-location
command to configure the output of the
show logging
command to include an additional
source field that displays the actual source of the alarm. The alarm source is displayed in a format that is
consistent with alarm source identification in other platforms and equipment. The new alarm source display
field aids accurate identification and isolation of the source of a fault.
By default, the output of the
show logging
command does not include the new alarm source identification
field. If you enable the alarm source location display field in the
show logging
output, the same naming
conventions are also used to display hardware locations in the
show diag
and
show inventory
command
output.
Customer OSS tools may rely on the default output to parse and interpret the alarm output.
Note
Task ID
Operations
Task ID
read, write
logging
Cisco IOS XR System Monitoring Command Reference for the Cisco XR 12000 Series Router, Release 4.1
OL-24735-01
29
Alarm Management and Logging Correlation Commands
logging events display-location