logging events threshold
To specify the logging events buffer threshold that, when surpassed, generates an alarm, use the
logging
events threshold
command in global configuration mode. To return to the default value, use the
no
form of
this command.
logging events threshold percent
no logging events threshold
Syntax Description
Minimum percentage of buffer capacity that must be allocated to messages before an
alarm is generated. Range is 10 to 100. The default is 80 percent.
percent
Command Default
percent
: 80 percent
Command Modes
Global configuration
Command History
Modification
Release
This command was introduced.
Release 3.2
Usage Guidelines
This command can be configured to generate an alarm when 10 percent or more of the event buffer capacity
is available.
The logging events buffer is circular; that is, when full it overwrites the oldest messages in the buffer. Once
the logging events buffer reaches full capacity, the next threshold alarm is generated when the number of
overwritten events surpasses the percentage of buffer capacity allocated to messages.
Use the
show logging events info, on page 62
command to display the current threshold setting.
Task ID
Operations
Task ID
read, write
logging
Examples
This example shows how to configure the threshold setting to 95 percent of buffer capacity:
RP/0/0/CPU0:router(config)#
logging events threshold 95
Cisco IOS XR System Monitoring Command Reference for the Cisco XR 12000 Series Router, Release 4.1
OL-24735-01
33
Alarm Management and Logging Correlation Commands
logging events threshold