8-34
Cisco TelePresence System Administration Guide
OL-21845-01
Chapter 8 Troubleshooting the CTS 1300
Managing CTS 1300 Hardware Setup
Positioning the Table and Starting the Calibration Procedure
To correctly position the table and configure the Cisco TelePresence software for use with the CTS 1300
cameras:
Step 1
Position the table so that there is a minimum of 44 inches between the display and the front of the table,
and make sure that the sides of the table are evenly positioned on each side of the CTS 1300.
Step 2
Make sure that the farthest edge of the table is no farther than 110 inches away from the lower bezel of
the display.
Figure 8-28
shows recommended table positioning.
Note
The table must be 28 to 32 inches high. 30 inches is the optimal height.
Figure 8-28
Short Racetrack Table Positioning
Step 3
Make sure that the camera assembly is level by completing the steps in the
“Removing the Camera Cover
and Leveling the Cameras” section on page 8-8
.
Step 4
Build the easel, and attach the large camera target to the easel, by completing the steps in the
“Attaching
the Large Camera Target to the Easel” section on page 8-11
, making sure that the bottom of the target is
32 inches above the ground.
Step 5
Log in to the Cisco TelePresence System Administration interface.
Step 6
Select the table type by completing the following steps:
a.
Choose Troubleshooting > Hardware Setup.
b.
Click the Configuration radio button.
c.
Click the Start button to start testing.
d.
Select Short Racetrack Table from the drop-down menu, as shown in
Figure 8-29
.
10 feet
30 inches
44 inches
minimum
6 feet minimum,
12 feet maximum,
8 feet recommended
206160
A=B
A
B