7-7
Cisco TelePresence System Administrator Guide
OL-21845-01
Chapter 7 Troubleshooting the CTS 1100
Managing CTS 1100 Hardware Setup
•
Attaching the Large Camera Target to the Easel
•
Positioning the Table and Starting the Calibration Procedure
•
Managing Focus Adjustments and Adjusting the Camera Zoom, page 7-10
•
Focusing the Camera
•
Saving Your Settings
•
Attaching the Camera Lens and Hood
Removing the Camera Cover and Leveling the Camera
The camera cluster must be perfectly level for you to properly configure the camera. To level the camera,
complete the following steps.
Step 1
Turn the four black plastic screws on the top and bottom of the camera assembly 1/4 turn, then remove
the camera cover, as shown in
Figure 7-3
.
Figure 7-3
Removing the Camera Cover
Step 2
Place the small
spirit level
on top of the camera assembly and adjust the leveling screws behind the
camera cluster until the camera assembly is level, as shown in
Figure 7-4
.
206623
Cover
release
screws
Cover
release
screws