8-8
Cisco TelePresence System Administration Guide
OL-21845-01
Chapter 8 Troubleshooting the CTS 1300
Managing CTS 1300 Hardware Setup
Testing the CTS 1300 Cameras
The CTS 1300 supports three cameras and various room configurations and table types. Use the
procedures in this section to troubleshoot the cameras depending on your table type.
Note
You must first configure the table size before you can test the camera. See the
“Configuring the CTS 1300 Table” section on page 8-3
. For more information about the supported table
types, see the
Supported Table Types and Minimum Room Dimensions
section of the
Cisco TelePresence
System 1300 Assembly, First-Time Setup, and Field-Replaceable Unit Guide
.
Note
If you log out of the Cisco TelePresence System Administration interface at any time during the camera
testing procedure, you must re-select the table type. To select the correct table type, complete the steps
in the
“Positioning the Table and Starting the Calibration Procedure” section on page 8-13
.
Use the information in the following sections to set up the CTS 1300 camera for testing:
•
Removing the Camera Cover and Leveling the Cameras, page 8-8
•
Attaching the Large Camera Target to the Easel, page 8-11
•
Configuring the CTS 1300 for Use With a Long Straight Table, Wide Rectangular Table, or Long
Racetrack table, page 8-13
•
Configuring the CTS 1300 for Use With a Short Racetrack Table, page 8-33
•
Saving Your Settings, page 8-44
Removing the Camera Cover and Leveling the Cameras
The camera cluster must be perfectly level for you to properly test the camera. To remove the camera
cover and level the camera:
Step 1
Remove the camera cover by removing the four black plastic screws on the top and bottom of the camera
assembly, as shown in
Figure 8-4
.