SIT Treatment for Call Classification (Category A only)
Issue 1.0 May 2003
313
SIT Ineffective Other
Sample announcement following this SIT — “You are not required to dial a “1” when calling
this number.” Valid entries are answered and dropped. Default is dropped.
SIT Intercept
Sample announcement following this SIT — “XXX-XXXX has been changed to YYY-YYYY,
please make a note of it.” Valid entries are answered and dropped. Default is answered.
SIT No Circuit
Sample announcement following this SIT — “All circuits are busy, please try to call again
later.” Valid entries are answered and dropped. Default is dropped.
SIT Reorder
Sample announcement following this SIT — “Your call did not go through, please hang up
and dial again.” Valid entries are answered and dropped. Default is dropped.
SIT Vacant Code
Sample announcement following this SIT — “Your call cannot be completed as dialed,
please check the number and dial again.” Valid entries are answered and dropped. Default
is dropped.
SIT Unknown
A situation or condition that is unknown to the network is encountered. Valid entries are
answered and dropped. Default is dropped.
AMD (Answering Machine Detected)
An ASAI adjunct can request AMD for a call. If Answering Machine is detected, one of two
treatments is specified. Valid entries are dropped and answered. Default is dropped.
AMD Treatment has two separately administrable subfields. Talk Duration is for full
seconds and Pause Duration is for fractions of a second, separated by a display-only
decimal point. Talk Duration defaults to 2.0 seconds and allows a range from 0.1 seconds
to 5.0 seconds in increments of 0.1 seconds. Pause duration defaults to 0.5 seconds and
allows a range from 0.1 seconds to 2.0 seconds in increments of 0.1 seconds.