Note
Action
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
Remove the cabling from the base.
3
xx1400000776
Remove the screws.
4
xx1400000777
Pull up the protection sleeve.
5
For robots with protection type Clean Room
6
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Tightening torque: 0.3 Nm.
Fit the new protection sleeve and secure with
screws.
7
Continues on next page
520
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the base spare parts (base, axis-1 radial sealing, protection sleeve)
Continued