Note
Action
Gasket for tubular cable housing cover:
3HAC056707-001 (not Hygienic robots) /
3HAC080701-001 (Hygienic robots)
xx1400000345
For robots with protection class IP67
For robots with protection type Foundry
Plus
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Check the tubular cable housing cover
gasket.
Replace if damaged.
2
Screws: 3HAB3409-207 (M3x8).
Refit the cover to the cable housing.
3
Tightening torque: 1.5 Nm.
xx1300002389
Note
Only use specified screws, never replace
them with other screws.
Continues on next page
Product manual - IRB 1200
635
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the swing spare parts (swing, axis-2 radial sealing)
Continued
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product manual IRB 1200 ...
Page 156: ...This page is intentionally left blank ...
Page 896: ...This page is intentionally left blank ...
Page 898: ...This page is intentionally left blank ...
Page 905: ......