Note
Action
PTFE film on cable housing cover:
3HAC044660-001
Check the PTFE film on the cable housing
cover.
6
Replace if damaged.
Apply grease to the inner surface of the
cable housing cover and the PTFE film
surface.
7
Screws: 3HAB3409-207 (M3x8).
Refit the cable housing cover.
8
Tightening torque: 1.5 Nm
xx1300002400
For robots with protection class IP67
For robots with protection type Foundry
Plus
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Apply locking liquid Loctite 243 to all the
screws securing the cover.
Note
Only use specified screws, never replace
them with other screws.
For robots with protection type Clean
Room
9
For robots with food grade lubrication
For robots with protection type Hygienic
Clean, seal and paint the joints that have
been opened. See
on the robot before replacing parts on
page 158
Note
After all repair work, wipe the robot free
from particles with spirit on a lint free cloth.
Calibration is detailed in section
.
Recalibrate the robot.
10
Continues on next page
684
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.3 Replacing the axis-3 drive unit
Continued
Summary of Contents for IRB 1200