Note
Action
xx1300000472
Pull out the base slightly and turn it aside.
Tip
Remember the cable layout in the base. The
cabling must be positioned and angled in the
same way during refitting.
5
Removing the cable package from the axis-1 sealing ring
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1300002438
Remove the axis-1 sealing ring from the swing
and carefully run the cable package out from the
swing.
3
Remove the swing (including arm system) com-
pletely from the base and lay it aside on a safe
location.
4
Continues on next page