Connecting the air hoses and CP/CS cabling (if equipped)
Notice that the procedure differs depending on the protection class and protection
type.
Connecting the air hoses and CP/CS cabling on robots not in protection type Hygienic
Use this procedure if the robot is not in protection type Hygienic.
Note
Action
For robots with protection type Clean Room
1
For robots with food grade lubrication
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Air connector set with Ethernet
hole in flange: 3HAC049664-001
Reconnect the air hoses.
Replace the air hose connector set if damaged.
2
Air connector set without Ethernet
hole in flange: 3HAC049665-001
xx1400000738
xx1500000252
If equipped, reconnect the CP/CS connector.
For robots with protection class IP67
For robots with protection type Foundry Plus
1
Check the gasket.
2
Replace if damaged.
For robots with protection type Clean Room
For robots with food grade lubrication
1
Remove residual locking liquid and other
pollutants with cleaning agent Loctite 7063.
2
Apply flange sealing Loctite 574 on the
mounting surfaces of the CP/CS connector
and wipe clean if there is any overflowing
Loctite 574.
3
On robots with protection class
IP67
On robots with protection type
Foundry Plus
Gasket: 3HAC058567-001
xx1500000251
Continues on next page
Product manual - IRB 1200
751
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.