Note
Action
Fit the radial sealing into the housing ex-
tender unit.
5
Axis-4 sealing assembly tool set:
3HAC049699-001
xx1400000436
Fit the circular part of the radial sealing
assembly tool against the radial sealing.
6
Fit the tool plate to the other side of the
housing extender unit with the six screws
M6X50.
7
xx1400000437
Screw the screws, little by little, to press
the sealing into place.
8
Remove the assembly tool.
9
Check that the sealing is undamaged and
properly fitted.
10
Refit both the axis-4 mechanical stop and
the axis-4 FPC unit to the housing extender
unit.
11
Refitting the housing extender unit
Note
Action
For robots with protection type Clean Room
1
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Continues on next page
708
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.4 Replacing the axis-4 gearbox, drive shaft and pulley
Continued