Note
Action
xx1600000219
For robots with protection type Clean Room
For robots with food grade lubrication
Make sure the sealing to the tilt covers is intact
before the refitting.
For robots with protection type Hygienic
Hygienic robots do not have tilt covers.
6
xx1600000220
Attachment screws: 3HAB3409-236
(M4x10).
xx1300002569
Refit the drive unit and secure with the screws
and washers.
Secure the screws but do not tighten yet.
Note
If there is glue on the screw, please clean it or
replace it with a new one.
7
Note
Only use specified screws, never
replace them with other screws.
xx1300002570
Remove the guide pins and refit the remaining
screws and washers.
8
Continues on next page
794
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.9 Replacing the axis-5 and axis-6 drive unit
Continued