Note
Action
Screws: 3HAB3409-207 (M3x8).
Refit the cable housing cover.
4
Tightening torque: 1.5 Nm.
xx1300002400
For robots with protection class IP67
For robots with protection type Foundry
Plus
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Apply locking liquid Loctite 243 to all the
screws securing the cover.
Note
Only use specified screws, never replace
them with other screws.
For robots with protection type Clean
Room
5
For robots with food grade lubrication
For robots with protection type Hygienic
Clean, seal and paint the joints that have
been opened. See
on the robot before replacing parts on
page 158
Note
After all repair work, wipe the robot free
from particles with spirit on a lint free cloth.
Calibration information is included in sec-
tion
.
Recalibrate the robot.
6
DANGER
Make sure all safety requirements are met
when performing the first test run.
7
Product manual - IRB 1200
307
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.3.4 Replacing the EIB/SMB unit
Continued