
Note
Action
Cable layout in IRB 1200-7/0.7 :
xx1300002412
Reconnect the FPC connectors and push them
into place inside the housing.
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Cable layout in IRB 1200-5/0.9 :
xx1400001471
Remove residual locking liquid and other pollut-
ants with cleaning agent Loctite 7063.
4
Continues on next page
Product manual - IRB 1200
443
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the axis-3 radial sealing and sealing ring
Continued
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product manual IRB 1200 ...
Page 156: ...This page is intentionally left blank ...
Page 896: ...This page is intentionally left blank ...
Page 898: ...This page is intentionally left blank ...
Page 905: ......