Note
Action
Screws: 3HAB3409-207 (M3x8).
Refit the cable housing cover.
13
Tightening torque: 1.5 Nm
xx1300002400
For robots with protection class IP67
For robots with protection type Foundry Plus
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Apply locking liquid Loctite 243 to all the screws
securing the cover.
Note
Only use specified screws, never
replace them with other screws.
Connecting the air hoses and CP/CS cabling (if equipped)
Notice that the procedure differs depending on the protection class and protection
type.
Connecting the air hoses and CP/CS cabling on robots not in protection type Hygienic
Use this procedure if the robot is not in protection type Hygienic.
Note
Action
For robots with protection type Clean Room
1
For robots with food grade lubrication
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Air connector set with Ethernet
hole in flange: 3HAC049664-001
Reconnect the air hoses.
Replace the air hose connector set if damaged.
2
Air connector set without Ethernet
hole in flange: 3HAC049665-001
xx1400000738
Continues on next page
Product manual - IRB 1200
447
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the axis-3 radial sealing and sealing ring
Continued
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product manual IRB 1200 ...
Page 156: ...This page is intentionally left blank ...
Page 896: ...This page is intentionally left blank ...
Page 898: ...This page is intentionally left blank ...
Page 905: ......