Hose for compressed air is also integrated into the manipulator. There are 4 inlets
at the base (R1/8”) and 4 outlets (M5) on the tubular housing.
(C)
(B)
(A)
(A)
(B)
(C)
xx1300000385
Value
Number
Description
Connection
Position
49 V, 500 mA
10
Customer power/signal
(R1)R4.CP/CS
A
Outer diameter of air hose:
4 mm
4
Max. 5 bar
Air
B
100/10 Base-TX
8
Customer Ethernet
(R1)R4.Ethernet
C
Connectors
The tables describes the connectors on base and tubular housing (upper arm).
Connectors, base
Art. no.
Description
Position
3HAC022117-002
Pin connector 10p, bulkhead
Robot
3HAC037038-001
Connector set R1.CP/CS
Customer connector
Connectors, tubular housing
Art. no.
Description
Position
3HAC023624-002
Socket connector 10p, flange mounted
Robot
3HAC037070-001
Connector set R3.CP/CS
Customer connector
Continues on next page
112
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
2 Installation and commissioning
2.7.2 Customer connections
Continued