Note
Action
Screw: 3HAB3409-238 (M6x35 (1
pc)).
xx1400000002
Refit the screw M6x35 (1 pc). Do not tighten yet.
4
Note
Only use specified screws, never
replace them with other screws.
Screw: 3HAB3409-237 (M5x35 (7
pcs)).
xx1400000003
Refit the rest of the screws (M5x35 (7 pcs)).
5
Note
Only use specified screws, never
replace them with other screws.
Tightening torque: 8 Nm.
Tighten all screws.
6
Tightening torque: 0.3 Nm.
xx1300002356
Put the cables through the plate hole and refit the
plate.
7
Continues on next page
484
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.7 Replacing the axis-4 mechanical stop
Continued