Note
Action
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1300002360
Snap loose the motor connectors from their
holders and then disconnect them.
•
R3.MP5
•
R3.ME5
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
3
Disconnecting the axis-5 FPC connectors
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
CAUTION
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of the robot! See
on the robot before replacing parts on
page 158
2
Continues on next page
Product manual - IRB 1200
579
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the swing spare parts (swing, axis-2 radial sealing)
Continued
Summary of Contents for IRB 1200