Note
Action
Radial sealing: 3HAC024865-001
xx1400000334
Fit the axis-3 radial sealing to the cable housing.
3
Axis-3 sealing assembly tool set:
3HAC049697-001
xx1400000335
Put the assembly tool on both sides of the cable
housing, circular part against the sealing, and
then slowly press the sealing into the housing by
screwing the six screws (M6X50) into the plate
little by little.
Fit the circular part of the radial sealing fitting tool
against the radial sealing.
4
Fit the tool plate to the other side of the cable
housing with the six screws M6X50.
5
Screw the screws, little by little, to press the
sealing into place.
6
Remove the assembly tool.
7
Continues on next page
Product manual - IRB 1200
435
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the axis-3 radial sealing and sealing ring
Continued
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product manual IRB 1200 ...
Page 156: ...This page is intentionally left blank ...
Page 896: ...This page is intentionally left blank ...
Page 898: ...This page is intentionally left blank ...
Page 905: ......