Note
Action
xx1400000452
Screw the screws, little by little, to press the
sealing into place.
6
Remove the assembly tool.
7
Check that the sealing is undamaged and properly
fitted.
8
Fitting lifting equipment to the upper and lower arm
Note
Action
CAUTION
The lower and upper arms together weigh 30 kg.
All lifting accessories used must be sized accord-
ingly!
1
Roundsling, 2 m
Fit lifting slings to the upper and lower arm.
2
Refitting the lower arm
Note
Action
For robots with protection type Clean
Room
1
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and
wipe the parts free from particles with
spirit on a lint free.
Continues on next page
604
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the swing spare parts (swing, axis-2 radial sealing)
Continued