Note
Action
xx1300002470
Remove the tilt unit.
6
Refitting the tubular
Use these procedures to refit the tubular.
Checking the sealing set on tool flange of Hygienic robots
Note
Action
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
1
xx2100001448
Check the gasket (A), seal ring unit (B) and
stainless shaft (C) on the tool flange.
Replace if damaged, as described below.
If undamaged and properly seated, skip to the
next procedure table.
2
xx2100001449
Remove the screws and washers.
3
Continues on next page
400
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.3 Replacing the tubular spare parts