xx1500001914
Tube insert
A
Plastic protection
B
Steel spring ring
C
Periodic check of the calibration tool
If including the calibration tool in a local periodic check system, the following
measures should be checked.
•
Outer diameter within Ø12g4 mm, Ø8g4 mm or Ø6g5 mm (depending on
calibration tool size).
•
Straightness within 0.005 mm.
xx1500000951
Outer diameter
A
Periodic check of the calibration tool for the tool flange (3HAC058238-001)
If including the tool flange calibration tool in a local periodic check system, the
following measures should be checked.
•
Outer diameter within Ø5g5 mm.
•
Straightness within 0.005 mm.
Continues on next page
822
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.4.2 Calibration tools for Axis Calibration
Continued