Note
Action
xx1300002391
Remove the connector plate by first removing the
screws.
4
xx1300002392
Remove the cable housing of the tubular by first
removing the screws.
Note
For robots with protection class IP67
For robots with protection type Foundry Plus
For robots with protection type Hygienic
The frame is glued and needs to be pried off.
5
Removing the axis-5 FPC unit
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1300002393
Remove the sleeve screws.
3
Continues on next page
Product manual - IRB 1200
281
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the axis-5 FPC unit
Continued
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product manual IRB 1200 ...
Page 156: ...This page is intentionally left blank ...
Page 896: ...This page is intentionally left blank ...
Page 898: ...This page is intentionally left blank ...