appendix2‑7
378
Commanded differential value in command units
Indicates the differential value of commanded in axis command units.
Unit:
1000*Axis command value/sec
DiffScmd
Dec
379
Actual differential value in command units
Indicates the actual differential value in axis command units.
Unit:
1000*Axis command unit/sec
DiffSfb
Dec
384
Bus voltage
Unit:
1/100 V
PM̲Voltage
Dec
385
Pre‑filtering current square duty
Indicates the instantaneous current square duty (I(superscript: 2)T) before motor heat model filter
processing (decimal point 15 bits). It becomes 100% at 32768 digits.
Unit:
digit
DutyI2
Dec
386
Post‑filtering current square duty
Indicates the average (time integrated instantaneous current square duty) current square duty
(I(superscript: 2)T) after motor heat model filter processing (decimal point 15 bits). It becomes 100%
at 32768 digits.
Unit:
digit
DutyI2F
Dec
390
Maximum command unit value
Unit:
Axis command unit
SposMax
Dec
391
Minimum command unit value
Unit:
Axis command unit
SposMin
Dec
392
Final home location from sensor edge
Indicates the distance between home position and edge of home sensor active region measured during
homing operation.
Unit:
pulse
OrgMeasure
Dec
TI 71M01D06‑01E 2nd Edition : 2007.01.10‑00