appendix2‑4
325
Commanded current value
Indicates the value of the current being commanded. The value is 4096 digits when maximum current is
commanded.
Unit:
digit
Icmd
Dec
326
Commanded current limit value
Indicates the value of commanded current in digits, limited by the torque/force function, when the
torque/force function is enabled (used). The value is 4096 digits when maximum current is commanded.
Unit:
digit
IcmdLimit
Dec
330
Commanded torque/force value
Indicates the value of the torque/force being commanded. The value for the maximum torque/force of the
monitor is at 8192 digits.
Unit:
digit
TFcmdF
Dec
331
Pre‑filtering commanded torque/force value
Indicates the the value of the torque/force being commanded before using phase delay compensation or
notch filter. The value becomes equal to maximum torque/force at 8192 digits.
Unit:
digit
TFcmd
Dec
333
Commanded acceleration feed forward value
Indicates the commanded accleration feed forward value.
Unit:
digit
Aff
Dec
340
Commanded velocity value
Indicates the velocity command value. Number in digits is converted to [rps] or [mps] by dividing by
the Velocity unit conversion coefficient monitor value.
Unit:
digit
Vcmd
Dec
341
Commanded post‑filtering velocity command value
Indicates the commanded velocity value after velocity command filter processing. Number in digits is
converted to [rps] or [mps] by dividing by the Velocity unit conversion coefficient (#303).
Unit:
digit
VcmdF
Dec
342
Actual velocity value
Indicates the actual velocity value. Number in digits is converted to [rps] or [mps] by dividing by
the Velocity unit conversion coefficient monitor value(#303).
Unit:
digit
Vfb
Dec