appendix1‑18
90
Coin window #0
Specifies the coin window #0 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth0
Dec
91
Coin window #1
Specifies the coin window #1 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth1
Dec
92
Coin window #2
Specifies the coin window #2 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth2
Dec
93
Coin window #3
Specifies the coin window #3 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth3
Dec
94
Coin window #4
Specifies the coin window #4 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth4
Dec
TI 71M01D06‑01E 2nd Edition : 2007.01.10‑00