6-82
TI71M01D06-01EN 3rd Edition: 2012.12.01
List of Homing Operation Data 0
Name Description
Default setting of
table numbers 3
and 63
Homing direction
Set the homing direction at homing operation
- direction
Coin width
Select the settling width at homing operation from coin widths 0 to 7 (#90 ~
#97).
Position settling
width 0
Select acceleration
time
Select the acceleration time from acceleration times 0 to 3 (#72 ~ #75).
Acceleration
time 0
Select deceleration
time
Select the deceleration time from deceleration times 0 to 3 (#76 ~ #79).
Deceleration
time 0
Select acceleration
type
Select either "constant acceleration" or "S-curved profile."
Constant
acceleration
Select deceleration
type
Select either "constant acceleration" or "S-curved profile."
Constant
acceleration
Hardware EOT limit
active in homing
operation
Set to [Enable] to perform hard EOT signal search movable using the EOT
sensor (connected to TB4) at the start of homing movement.
Set to [Disable] if the EOT sensor is not used.
[Disable]
Enable home sensor
Specify [Enable] under normal circumstances. If it is set to [Disable], home
sensor search movement is not performed. The home position is set to the
position at which the rising edge of the Z-pulse is detected.
[Enable]
Enables the home
sensor during EOT
search
Only valid when [Hardware EOT active] is set to [Valid]. This parameter
specifies whether or not to switch to home search movement if the home
sensor is detected during hardware EOT signal search movement during
the homing operation.
[Invalid]
Select home sensor
inside
Select the edge of the Z-pulse to be set as the home position.
Z-pulse
⇐
CW direction
CCW direction
[Inside]
Home
proximity
sensor
Edge when
[Inside]
is selected
Edge when
[Outside]
is selected
ON
OFF
ON
OFF